Couldn't load pickup availability
Ventis MX4 Multi-Gas Detector Safety Orange H2S/CO/O2/LEL (VTS-K1231201y0z)
BE READY FOR THE MOMENT In your line of work, a day on the job can turn from habit to hazard in a single moment. Be ready for anything with the Ventis™ Pro Series Multi-Gas Monitors.
Monitor up to five gases with flexible sensor configuration options
With features that keep users safer than ever, the Ventis™ Pro5 makes owning and using gas detectors easy– all in a highly configurable and incredibly compact multi-gas monitor.
Stop carrying multiple devices to meet your gas detection needs. The Ventis Pro5 offers a variety of sensor options with flexible slot positions to help you detect combustible and toxic gases across a range of applications.
Save precious time in emergency situations by quickly alerting nearby workers when someone is in distress or has lost consciousness.
Keep your instruments in the field, not the shop, thanks to an all-new overmold design and Guaranteed for Life™ warranty.
Address recurring alarms, identify hazards, and improve asset management by assigning users and sites to each gas monitor in real time with iAssign™ Technology.
Communicate key safety information to your team, simplify the user’s response when an instrument goes into alarm, and reduce nuisance alarms and false evacuations thanks to customizable text options.
| Specification | Detail Description |
|---|---|
| TYPICAL RANGE OF GASES DETECTED | |
| CATALYTIC BEAD | |
| Combustible Gases | 0-100% LEL in 1% increments |
| Methane (CH4) | 0-5% of vol in 0.01% increments |
| ELECTROCHEMICAL | |
| Ammonia (NH3) | 0-500 ppm in 1 ppm increments |
| Carbon Monoxide (CO) | 0-2,000 ppm in 1 ppm increments |
| Carbon Monoxide (CO/H2 low) | 0-1,000 ppm in 1 ppm increments |
| Carbon Monoxide/Hydrogen Sulfide | DUOTOX |
| CO | 0-1,500 ppm in 1 ppm increments |
| H2S | 0-500 ppm in 0.1 ppm increments |
| Hydrogen Sulfide (H2S) | 0-500 ppm in 0.1 ppm increments |
| Hydrogen Cyanide (HCN) | 0-30 ppm in 0.1 ppm increments |
| Nitrogen Dioxide (NO2) | 0-150 ppm in 0.1 ppm increments |
| Oxygen (O2) | 0-30% of vol in 0.1% increments |
| Sulfur Dioxide (SO2) | 0-150 ppm in 0.1 ppm increments |
| INFRARED | |
| Carbon Dioxide/Hydrocarbons | Dual IR Cell |
| CO2 | 0-5% vol in 0.01% increments |
| HC | 0-100% LEL in 1% increments |
| Carbon Dioxide/Methane | Dual IR Cell |
| CO2 | 0-5% vol in 0.01% increments |
| CH4 | 0-5% vol in 0.01% increments |
| CH4 | 5-100% vol in 0.1% increments |
| GENERAL SPECIFICATIONS | |
| KEYPAD | Two buttons for operation. Dedicated panic button. |
| DATA LOG | At least 3 months at 10-second intervals |
| EVENT LOGGING | 60 alarm events |
| INGRESS PROTECTION | IP68 (submersion at 1.5 meters for 1 hour) |
| CASE MATERIAL | Polycarbonate with protective rubber overmold |
| DIMENSIONS | 104 x 58 x 36 mm (4.1 x 2.3 x 1.4 in) without pump |
| 172 x 67 x 65 mm (6.8 x 2.6 x 2.6 in) with pump | |
| WEIGHT | 200 g (7.05 oz), typical without pump |
| 390 g (13.76 oz), typical with pump | |
| TEMPERATURE RANGE | -40 °C to 50 °C (-40 °F to 122 °F) |
| HUMIDITY RANGE | 15%-95% non-condensing (continuous) |
| DISPLAY/READOUT | Backlit liquid crystal display (LCD) |
| POWER SOURCE/RUN TIME | Rechargeable lithium-ion battery pack with LEL |
| (12 hours typical @ 20 ºC) – without pump | |
| Rechargeable extended-range lithium-ion battery pack with LEL | |
| (24 hours typical @ 20 ºC) – without pump | |
| (18 hours typical @ 20 ºC) – with pump | |
| Rechargeable lithium-ion battery pack with IR | |
| (36 hours typical @ 20 ºC) – without pump | |
| Rechargeable extended-range lithium-ion battery pack with IR | |
| (72 hours typical @ 20 ºC) – without pump | |
| (32 hours typical @ 20 ºC) – with pump | |
| ALARMS | Four visual alarm LEDs (two red, two blue); 95 decibel (dB) audible alarm at a distance of 10 cm (3.94 in); Vibration alarm |
| SENSORS | Combustible Gases/Methane – Catalytic Bead. O2, CO, CO/H2 low, H2S, HCN, NH3, NO2, SO2 – Electrochemical. CO2/HC, CO/CH4 - Infrared |
| CERTIFICATIONS | |
| UL | Class I, Division 1, Groups A, B, C, and D, in the Temperature Class T4 |
| Class II, Division 1, Groups E, F, and G, in the Temperature Class T4 | |
| Class I, Zone 0, AEx ia IIC, in the Temperature Class T4 | |
| Class I, Zone 1, AEx d ia II C, in the Temperature Class T4, with IR sensor | |
| ATEX | Equipment Group and Category II 1G, Ex ia IIC, with the protection category Ga, in the Temperature Class T4 |
| Equipment Group and Category II 2G, Ex d ia IIC, with the protection category Gb, in the Temperature Class T4, with IR sensor | |
| IECEx | Class I, Zone 0, Ex ia IIC, with the protection technique Ga, in the Temperature Class T4 |
| Class I, Zone 1, Ex d ia IIC, with the protection technique Gb, in the | |
| Temperature Class T4, with IR sensor | |
| CSA | Class I, Division 1, Groups A, B, C, and D, in the Temperature Class T4 |
| Class I, Zone 1, Ex d ia IIC, in the Temperature Class T4 | |
| SUPPLIED WITH MONITOR | Calibration Cup (Ventis), Sample Tubing (Ventis with pump), Reference Guide |
| REFERENCE GUIDE LANGUAGE | English, French, Spanish, German |
| WARRANTY | Guaranteed for Life. Warranted for as long as the instrument is supported by Industrial Scientific Corporation (excludes sensors, batteries, and filters). O2, LEL, CO, and H2S sensors warranted for three years. All other sensors warranted for two years. Pumps and batteries are warranted for two years. |
Orders marked "In Stock" are typically shipped within 12-24 hours.
Delivery is usually made within 1-7 business days, depending on the destination and item weight.
Flat shipping fee applies for all orders up to a certain weight limit.
Thanks for subscribing!