How to Don PAPR: A Comprehensive Guide for Safety
Understanding PAPRs
Powered air-purifying respirators (PAPRs) are respiratory protection devices utilizing battery-driven blowers to draw air through filters, delivering clean air to a hood or facepiece. This system contrasts with negative-pressure varieties by lowering breathing effort, which particularly benefits workers with facial hair or certain medical conditions through loose-fitting hoods. Compliance with OSHA’s respiratory protection standard, 29 CFR 1910.134, requires developing a written program, undergoing medical evaluations, and conducting necessary fit testing and training. Furthermore, maintenance plays a crucial role in ensuring reliable protection. Use only configurations approved by NIOSH, verified by checking approval labels before deployment.
PAPRs are ideal when airborne contaminants necessitate higher assigned protection factors or when heat stress during extended shifts heightens breathing resistance. A beard that prevents a proper seal further warrants utilizing PAPR systems. OSHA’s APF values range from 25 for loose-fitting options to 1,000 for tight, full-face powered models if approved and used correctly. Industries like healthcare, pharmaceutical production, welding, construction, and hazmat spill response often integrate these respirators, tailoring protocols post-hazard assessment.
Donning Overview: Inspect battery, blower, hose, headgear, and cartridges; confirm NIOSH approval. After donning the belt unit, start airflow, noting the device indicator or hood air movement for verification. Wear headgear, ensuring no hose kinks, and execute a seal check for tight-fitting facepieces; add PPE when required by standard operating procedures. Find CDC step-by-step demonstrations for PAPR assemblies within healthcare modules and general PPE sequence guidelines.
Appropriate Use: PAPRs should be selected for aerosol-generating procedures, spill cleanups, high-particulate fabrication, or when fit testing for filtering facepieces or elastomeric options fails. Align use with OSHA program mandates.
Doffing Process: In an appointed removal area, discard exterior gloves (if double-gloved), clean hood surfaces, and follow power-down steps per manufacturer guides. Carefully detach hose and headgear, clean designated areas, and remove the belt unit. Perform hand hygiene and remove inner gloves. Employ a trained observer for high-risk healthcare workflows.
Sources
- OSHA Respiratory Protection Standard 29 CFR 1910.134
- OSHA Respiratory Protection Hub
- CDC/NIOSH PAPR Resource
- CDC PPE Donning/Doffing Sequence
- Wikipedia Overview
Comprehensive Guide to Donning a PAPR
Putting on a Powered Air-Purifying Respirator (PAPR) necessitates strict adherence to manufacturer instructions and compliance with OSHA 29 CFR 1910.134 alongside NIOSH requirements. These devices form a critical part of workplace safety, with selection and upkeep aligning with detailed program guidance from both NIOSH and the employer’s written protocols. Each model may possess unique steps, so ensure procedures align with product documentation and site guidelines.
Inspection:
Start by confirming the presence of NIOSH approval markings, checking for cleanliness, intact gaskets, undamaged hoses, and charged power sources. Verify that filters or cartridges are in-date and alarms are legible. Consult the NIOSH Trusted-Source for approval specifics.
Assembly:
Secure the waist belt, attach the breathing tube properly, and follow labeling to install cartridges or filters, ensuring the interface aligns with threading or bayonet connections.
Airflow Check:
Activate the blower and use the provided indicator or test function to ensure adequate airflow. Replace components if the rate falls short. Detailed performance criteria are available in the NIOSH Science Blog.
Headgear Positioning:
Fit the hood or helmet ensuring the shroud fully covers the collar and shoulders without gaps. Smooth the fabric, align the visor for unobstructed vision, and ensure hoses stay kink-free.
Tight-Fitting Facepiece Models:
For models needing a tight seal, apply the facepiece by positioning the chin then the crown, evenly adjusting strap tension. Avoid overtightening which may distort the skirt. Conduct a user seal check in accordance with OSHA Appendix B-1.
Harness Adjustment:
Adjust belt height, manage slack, and ensure hose clearance avoids sharp edges. Confirm compatibility with hard hats, eyewear, or hearing protection.
Functional Verification:
Validate the operation of low-flow and battery alarms. Carry spare charged power if required by policy, and have adapters and caps ready for cartridge swapping.
In-Use Protocol:
Maintain facepiece seal integrity by keeping hands clear. Alarms or dropping airflow necessitate component replacement.
Challenges of PAPR Use:
Users often report challenges related to battery dependency, blower noise, bulkiness, and communication barriers, with some tasks experiencing heat burden and snag risks (NIOSH Science Blog). When selecting respirators, program owners should consider these factors alongside task demands and other PPE compatibility (OSHA 1910.134; Wikipedia overview).
---